0.7T, 1.5T, 3.0T MR Entree® Buildings
The USA Trademarked Entree buildings are the only Underwriters
Laboratories, Inc., (UL)® classified material component
and UL® classified component design modular structures
on the market. These modular buildings are the only fully
movable modular buildings available on the market for MR,
CT, ANGIO-CATH, CT/PET and PET imaging.
Thoroughly tested to meet both mobile and "site construction"
standards, the Entree modules are the ideal imaging environments
for MR equipment in a modular configuration. No longer do
the words "modular building" need to imply fast, cheap and
unattractive. The Entree modular buildings are where high
building quality and reasonable price intersect to provide
the BEST VALUE in a diagnostic imaging module.
The MR Entree is the only, institutional code compliant,
Diagnostic Imaging Module that is shipped within 12 weeks
as a "fully finished" relocatable building with a fully
installed MR system.
- MR Systems
Entree modules are designed and engineered specifically
for 1.0T , 1.5T and 3.0T MR systems as well as 0.35T and
0.7T MR systems. (Consult PDC for exceptions)
- Imaging Performance
Guaranteed "fixed site imaging performance" in a modular
building.
- Simplicity
Entree and MR system can be ordered on a single purchase
order issued to the equipment vendor. Site construction
is a simple concrete foundation slab.
- Preinstalled MR System
The only "fixed site" MR magnet and system that is delivered,
fully installed, in a building. MR system can be "transplanted"
into another building. The Entree can be sold and reused.
(Consult PDC for exceptions)
- Timely Sales Transfers
The fully installed MR system in the fully finished modular
building is delivered within 12 weeks from date of order
acceptance. (Consult PDC for exceptions)
- USA Federal Compliance
The only modular building that meets all USA Federal Design
Guidelines; Joint Commission (JCHA) requirements and State
Health Department regulations for hospital in-patients.
- Hospital Compatibility
Hospital code compliant and National Fire Protection Association
(NFPA) standards allowing installation immediately adjacent
to a hospital to minimize siting costs.
- National Design Code Compliance
Meets all state building codes including BOCA; UBC; ICBO;
SBCCI and all US Federal regulations relating to ADA and
OSHA requirements.
- International Building& IBC Compliance
Meets all IBC requirements throughout the USA.
- EMI & Magnetic Shielding
Standard magnetic shielding to contain 1,3,5,10 Gauss
within the scan room along with the only non oxidizing
RF enclosure featuring a Limited LIFETIME Warranty. (Consult
PDC for exceptions)
- Up-Gradable & Relocatable
Designed for "forward production" MR system up-grades
from 1.5T to 3.0T as well as building relocation without
the requirement to de-install the MR magnet and system.
(Consult PDC for exceptions)
- Turnkey Services
The Entree program provides complete site plan design
information as well as transportation and rigging coordination
to expedite a project time schedule.
- Full Warranty
A full One Year building warranty with extended OEM mechanical
warranties.
* program details vary
|